|  | Motor Connecting Cables |  | |
|  | |||
| 2YSLCY-JB/2YSLCYK-JB |  |  | 9YSLCY-JB |  | PENDANT CABLE |  | 
 Mineral insulated cables
Mineral insulated cables
      Constant Wattage Heating Cable up to 260 °C
Application
Vessels, piping, valves
Food processing industry
Frost protection and temperature maintenance on pumps
Standard
DIN VDE 0721-52
EN 62395-1; 2007-05
Voltage Rating
230V
CABLE CONSTRUCTION

Bus wire.
Insulation: Fluoropolymer.
Heating conductor.
Protective: Nickel-plated copper braid.
Outer sheath: Fluoropolymer.
Mechanical and Thermal Properties
Nominal temperature: 260℃
Minimum installation temperature: -45℃
Minimum start-up temperature: -45℃
Bus wire cross section: 2x1.5 mm²
Minimum bending radius: 25mm
Cable Parameter
| APPROX. | Contact spacing m | Nominal output W/m | Maximum working temperature | Maximum heating circuit length m | |
|---|---|---|---|---|---|
| 
 at 50 °C | 
 at 150 °C | ||||
| 8.0x5.5 | 1.0 | 15 | 205 | 161 | 119 | 
| 8.0x5.5 | 1.0 | 30 | 190 | 98 | 82.5 | 
| 8.0x5.5 | 1.0 | 45 | 175 | 65.5 | 65.5 | 
| 8.0x5.5 | 1.0 | 60 | 160 | 50 | 50 | 